Clarke 195TE Spécifications Page 2

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 31
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 1
2
PRIMARY or INPUT POWER DATA
MIG195TE MIG205TE MIG230TE
Primary Volts 230V/1PH 230V/1PH 230V/1Ph
Primary Amps 24 Amps 24 Amps 28 Amps
Frequency 50 HZ 50 HZ 50Hz
SECONDARY or OUTPUT POWER DATA
Sec. Volts 23-44 V 23-30 V 23-46 V
Max. Sec. Amps 185 185 210
Current Range 30-185 30-185 30-210
DUTY CYCLES
100% 80 Amps 60 Amps 80 Amps
60% 103 Amps 80 Amps 103 Amps
20% 170 Amps -- --
16% -- -- 200 Amps
12% -- 65 Amps --
NOTE: Duty Cycles are rated over a 10 minute period.
Example: If welding with a MIG 205TE at 80amps, a 60% duty cycle applies. This
means that over a 10 minute period, the welding time is 6 minutes, the down time
is 4 minutes.
USABLE WIRE SIZES
Mild Steel Wire 0.6-0.8mm 0.6-0.8mm 0.6-0.8mm
Stainless Steel Wire 0.8mm 0.8mm 0.8mm
Aluminium Wire 0.8mm 0.8mm 0.8mm
USABLE GASES MAIN USES
75% Argon 25% CO
2
- Thin Sheet Metal, Mild Steel
100% Argon - Welding Aluminium, Stainless Steel
100% CO
2
- Mild Steel
The details and specifications contained herein, are correct at the time of going to print. However, CLARKE
International reserve the right to change specifications at any time without prior notice. Consult ma-
chines data plate.
WELDER SPECIFICATIONS