Clarke PSE2A Spécifications Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 11
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
10
CLEANING AND MAINTENANCE
WARNING!
MAKE SURE THAT THE PUMP IS DISCONNECTED FROM THE MAINS SUPPLY
BEFORE CLEANING, OR PERFORMING ANY MAINTENANCE.
These pumps should require no maintenance other than regular cleaning. If the
pump starts to show signs of wear or damage, contact your CLARKE dealer for
advice.
Do not attempt to repair the pump yourself, repairs must be carried out by your
CLARKE dealer, or contact the CLARKE Service Department, on 020 8988 7400.
Check the pump regularly to ensure the base is clear of leaves or other debris.
Replacing the Impeller
1 Remove the 3 screws on the base of the
pump, and remove the cover.
2 Use a small flat headed screwdriver to
remove the circlip.
3 Pull the old impeller off of the shaft.
4 Replace with a new impeller and lock it in
place using the circlip.
5 Replace the base and use the 3 screws to
secure.